Skip to main content

Efficacy of non-obstructive aortic angioscopy for detecting a thoracic aortic graft rupture: a case report

Abstract

Background

Non-anastomotic thoracic aortic graft rupture is extremely rare and difficult to diagnose. Non-obstructive general angioscopy can help monitor the aortic intima and detect the locations of abnormal findings, while aortic angioscopy can detect vulnerable plaques in the aorta, which are difficult to visualize using conventional diagnostic methods. Herein, we report the case of a patient with non-anastomotic thoracic aortic graft rupture diagnosed using non-obstructive aortic angioscopy.

Case presentation

An 85-year-old man who had undergone total arch replacement 5 years prior complained of chest pain. Emergent contrast-enhanced computed tomography (CT) revealed an intra-mediastinal hematoma around the vascular graft of the ascending aorta and angiography revealed pooling of contrast medium on the dorsal side of the vascular graft. We suspected extravasation of the thoracic vascular graft. Aortic angioscopic examination revealed a red vascular graft defect that matched extravasation at the contralateral level of the prosthetic left common carotid artery branch. Subsequently, non-anastomotic thoracic aortic graft rupture was diagnosed. The patient underwent a two-debranching thoracic endovascular aortic repair (Zone 0) with a right subclavian artery-left common carotid artery-left subclavian artery bypass. Postoperative angiography revealed disappearance of the extravasation from the graft rupture site, patent grafted vessels with flow, and no endoleak. Follow-up CT at 6 months postoperatively showed no extravasation.

Conclusions

To our knowledge, this is the first report of non-anastomotic thoracic aortic graft rupture detected using non-obstructive aortic angioscopy. Aortic angioscopy can help establish a definitive diagnosis in patients with aortic graft rupture.

Background

Disruption of prosthetic vascular grafts can be divided into two major categories: anastomotic and non-anastomotic failures. To date, most reports have focused on anastomotic failures associated with infections [1]. There are few reports of non-anastomotic graft rupture in contemporary vascular prostheses that is caused by mechanical stress in areas, such as the groin and subclavian regions [2]. Furthermore, non-anastomotic graft rupture is extremely rare in a thoracic lesion, which makes it difficult to detect the site of disruption, especially during an emergency.

Although conventional imaging modalities, such as computed tomography (CT), magnetic resonance imaging (MRI), and transesophageal echocardiography (TEE) have been used to diagnose aortic diseases, the ability to detect millimeter-sized plaques is limited because of the relatively poor spatial resolution [3, 4]. Moreover, very few modalities can completely detect intimal injury or vulnerable plaques of the aorta in-vivo.

Herein, we report the case of a patient with non-anastomotic rupture of a prosthetic vascular graft that was diagnosed using non-obstructive aortic angioscopy which is known to help monitor the aortic intima and locations of abnormal findings.

Case report

An 85-year-old man with a history of total aortic arch replacement performed using a 26-mm, four-branched Triplex graft (Vascutek Terumo, Tokyo, Japan) for an aortic arch aneurysm 5 years previously, was admitted to the emergency department with chest pain.

Laboratory data exhibited anemia (Hb 9.4 mg/dL), elevated inflammatory markers (WBC 8500 /μL, CRP 5.5 mg/dL), near normal renal function, elevated bilirubin level (total bilirubin 5.6 mg/dL, direct bilirubin 2.9 mg/dL), and negative blood culture results. TTE confirmed an ejection fraction of 60% and mild aortic valve regurgitation without any tamponade sign.

Emergent contrast-enhanced CT revealed an intra-mediastinal hematoma around the vascular graft of the ascending aorta and extravasation on the dorsal side of the center of the vascular graft (Fig. 1A, B).

Fig. 1
figure 1

Contrast-enhanced CT findings. An intra-mediastinal hematoma around the vascular graft of the ascending aorta and extravasation on the dorsal side of the center of the vascular graft (black arrows). A Sagittal view; B Axial view

Emergent angiography, which was performed under general anesthesia in a hybrid operating room, revealed pooling of contrast medium on the dorsal side of the vascular graft. However, the source of the leak was unclear. Aortic angioscopic examination of the graft was performed using a non-obstructive angioscopy system (FT-203F angioscope and VISIBLE fiber; Fiber Tech Co., Ltd., Tokyo, Japan). This revealed a red vascular graft defect (Additional file 1: Video S1, Fig. 2A) that matched the simultaneous angiographic extravasation at the contralateral level of the prosthetic left common carotid artery (CCA) branch (Fig. 2B). A distance of 2 cm between the first branch of the graft vessel and rupture site was confirmed using a marker catheter.

Fig. 2
figure 2

Intraoperative aortic angiography and aortoscopic findings. Aortic angioscopy shows a red graft rupture site (A) that matches the pooling of contrast medium (black arrow) observed on simultaneous angiography using a non-obstructive angioscopy system (white arrow) at the contralateral level of the left common carotid artery branch contralateral level (B). Post-deployment angiography shows no extravasation (C)

We confirmed non-anastomotic graft rupture and immediately started two-debranching thoracic endovascular aortic repair. The left CCA and left subclavian artery (SCA) were revascularized via right SCA-left CCA-left SCA bypass using an 8-mm T-shaped ring-enforced polytetrafluoroethylene graft. A cTAG stent-graft (34 mm × 150 mm; W.L. Gore and Associates, Flagstaff, AZ) was deployed just distal to the first graft branch of the brachiocephalic artery via a femoral approach.

Finally, embolization at the left SCA was performed using the Vascular Plug (12 mm), and the proximal left CCA of the bypass anastomosis was closed with a Hem-o-lok XL (Research Triangle Park, NC, USA). A final angiography revealed the disappearance of the extravasation from the graft rupture site, patent flow to the grafted vessels, and no endoleak (Fig. 2C). The postoperative course was uneventful. He was transferred for rehabilitation in postoperative day 13. Follow-up CT at 6 months postoperatively showed no extravasation (Fig. 3).

Fig. 3
figure 3

Postoperative computed tomography findings. Postoperative computed tomography shows no extravasation

Discussion

Rupture after thoracic aortic surgery is usually caused by anastomotic failure. The literature reports a frequency of 1–12%, and the diagnosis is usually made 8–10 years after the original surgery [5]. As a differential diagnosis, rupture of an artificial vascular graft may occur although it has not been reported in the thoracic region. The most reported cause of graft rupture is infection. Moreover, there are reports of physical damages caused by aging, suturing during a previous surgery, calcification of the wrapped aorta, and contact with the ribs [6,7,8,9].

In this case report, blood tests at the time of admission showed elevated inflammatory markers but negative blood culture results. Therefore, infection was ruled out as a cause for the graft rupture.

In addition, the rupture site of the vascular prosthetic graft was on the dorsal side of the prosthetic graft, and aortic wrapping was not performed in the previous surgery. Therefore, it is unlikely that the graft rupture was caused by physical damage, and the cause of graft rupture was unknown.

Furthermore, a rupture site is sometimes difficult to detect despite using CT or angiography especially in the emergent case. When the rupture site is a proximal anastomosis, open surgery is the only treatment option. However, it is possible to perform endovascular treatment for a rupture of the graft itself or the distal anastomosis site. Therefore, detection of the rupture site was crucial in our case, because the patient had a high risk of open repair due to age and frailty.

Graft rupture was suspected on imaging. However, since graft rupture is extremely rare, we had to make a definitive diagnosis. Therefore, we prepared to treat the patient as soon as the rupture site was confirmed and performed angioscopy in the hybrid operating room. Angioscopy helped determine the rupture site and we immediately started two-debranching thoracic endovascular aortic repair.

Non-obstructive general angioscopy is a novel method that may have important implications for the diagnosis and management of vulnerable atherosclerotic plaque [10, 11]. Furthermore, this modality can help monitor the aortic intima and locations of abnormal findings in patients with a shaggy aorta and chronic type B aortic dissection [12], which are difficult to visualize using conventional diagnostic methods. Therefore, angioscopy has been used in endovascular therapy to confirm the location of arteriosclerotic plaques to prevent embolisms during aneurysm treatment or confirm the location of primary entry and re-entry in cases of aortic dissection [10, 12]. In the current case, aortic angioscopic examination of the graft was performed using a non-obstructive angioscopy system, as previously reported [10]. This revealed the rupture site to be a red thrombus on the vascular graft, while the graft wall around the distal anastomosis to the rupture site was intact. These findings have not been previously reported.

Conclusion

We reported the efficacy of non-obstructive aortic angioscopy for definitive diagnosis in a patient with graft rupture.

Abbreviations

CT:

Computed tomography

MRI:

Magnetic resonance imaging

TEE:

Transesophageal echocardiography

LCCA:

Left common carotid artery

LSCA:

Left subclavian artery

References

  1. Wilson SE, Krug R, Mueller G, Wilson L. Late disruption of Dacron aortic grafts. Ann Vasc Surg. 1997;11:383–6. https://doi.org/10.1007/s100169900065.

    Article  CAS  PubMed  Google Scholar 

  2. Okada N, Oshima H, Narita Y, Usui A. Nonanastomotic rupture of a woven polyester graft caused by a tacking stitch after aortic arch replacement. Ann Thorac Surg. 2015;100:2370. https://doi.org/10.1016/j.athoracsur.2015.09.007,26652541.

    Article  PubMed  Google Scholar 

  3. Tabata M, Shimokawa T, Fukui T, Manabe S, Sato Y, Takanashi S. New uncoated vascular prosthesis reduces mediastinal tube drainage after thoracic aortic surgery. Ann Thorac Surg. 2011;91:899–902. https://doi.org/10.1016/j.athoracsur.2010.11.030.

    Article  PubMed  Google Scholar 

  4. Shingu Y, Aoki H, Ebuoka N, Eya K, Takigami K, Oba J. Late rupture of knitted Dacron graft. Ann Thorac Cardiovasc Surg. 2005;11:343–5.

    PubMed  Google Scholar 

  5. Sachdev U, Baril DT, Morrissey NJ, Silverberg D, Jacobs TS, Carroccio A, et al. Endovascular repair of para-anastomotic aortic aneurysms. J Vasc Surg. 2007;46:636–41. https://doi.org/10.1016/j.jvs.2007.05.032.

    Article  PubMed  Google Scholar 

  6. Kawata M, Morota T, Takamoto S, Kubota H, Kitahori K. Non-anastomotic rupture in the guideline of a Dacron thoracic aortic graft. J Vasc Surg. 2005;42:573. https://doi.org/10.1016/j.jvs.2004.05.025.

    Article  PubMed  Google Scholar 

  7. Okada N, Oshima H, Narita Y, Usui A. Non anastomotic rupture of a woven polyester graft caused by a tacking stitch after aortic arch replacement. Ann Thorac Surg. 2015;100:2370. https://doi.org/10.1016/j.athoracsur.2015.09.007.

    Article  PubMed  Google Scholar 

  8. Oshima H, Abe T, Narita Y, Usui A. Non-anastomotic rupture of the valsalva graft 6 years after undergoing the Bentall procedure. Interact Cardiovasc Thorac Surg. 2016;23:668–70. https://doi.org/10.1093/icvts/ivw195.

    Article  PubMed  Google Scholar 

  9. Tanaka H, Okada K, Yamashita T, Kawanishi Y, Matsumori M, Okita Y. Disruption of the vascular prosthesis caused by aortic calcification after replacement of the thoracoabdominal aortic aneurysm. Ann Thorac Surg. 2006;82:1097–9. https://doi.org/10.1016/j.athoracsur.2006.01.040.

    Article  PubMed  Google Scholar 

  10. Komatsu S, Ohara T, Takahashi S, Takewa M, Minamiguchi H, Imai A, et al. Early detection of vulnerable atherosclerotic plaque for risk reduction of acute aortic rupture and thromboemboli and atheroemboli using non-obstructive angioscopy. Circ J. 2015;79:742–50. https://doi.org/10.1253/circj.CJ-15-0126.

    Article  PubMed  Google Scholar 

  11. Kojima K, Kimura S, Hayasaka K, Mizusawa M, Misawa T, Yamakami Y, et al. Aortic plaque distribution, and association between aortic plaque and atherosclerotic risk factors: an aortic angioscopy study. J Atheroscler Thromb. 2019;26:997–1006. https://doi.org/10.5551/jat.48181.

    Article  PubMed  PubMed Central  Google Scholar 

  12. Nishi H, Higuchi Y, Takahashi T, Domae K, Inoguchi K, Kawasumi R, et al. Aortic angioscopy assisted thoracic endovascular repair for chronic type B aortic dissection. J Cardiol. 2020;76:60–5. https://doi.org/10.1016/j.jjcc.2020.02.011.

    Article  PubMed  Google Scholar 

Download references

Acknowledgements

Not applicable.

Funding

Not applicable.

Author information

Authors and Affiliations

Authors

Contributions

All authors read and approved the final manuscript.

Corresponding author

Correspondence to Fumio Yamana.

Ethics declarations

Ethics approval and consent to participate

This report was approved by the Institutional Review Board.

Consent for publication

Informed consent was obtained from the patient for the publication of this case report and accompanying images.

Competing interests

The authors have no conflicts of interest.

Additional information

Publisher's Note

Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Supplementary Information

Additional file 1: Video S1.

Rights and permissions

Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/.

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Yamana, F., Maeda, K., Hamanaka, Y. et al. Efficacy of non-obstructive aortic angioscopy for detecting a thoracic aortic graft rupture: a case report. surg case rep 8, 41 (2022). https://doi.org/10.1186/s40792-022-01394-w

Download citation

  • Received:

  • Accepted:

  • Published:

  • DOI: https://doi.org/10.1186/s40792-022-01394-w

Keywords