- Case Report
- Open access
- Published:
Late esophageal wall injury after mesh repair for large esophageal hiatal hernia: a case report
Surgical Case Reports volume 3, Article number: 125 (2017)
Abstract
Background
Plication of an esophageal hiatus during surgery for esophageal hiatal hernia is a common practice; however, a mesh may be used if the hiatus is markedly enlarged. Recently, various late complications occurring as a result of mesh-induced esophageal and/or gastric wall injuries have been reported.
Case presentation
A 71-year-old woman presented at a neighborhood clinic in November 2010 with chief complaints of respiratory distress on exertion and heartburn. She was diagnosed as having a large esophageal hiatal hernia and was treated at our hospital using a laparoscopic Toupet fundoplication with mesh repair of the esophageal hiatus. Two years and 1 month after the operation, the patient complained of a bowel obstruction. An upper gastrointestinal endoscopy revealed that part of the mesh had extruded into the esophageal lumen, resulting in ulceration and stricture of the esophageal wall. Endoscopic balloon dilatation failed to improve the esophageal stricture. In July 2012, the patient underwent a lower esophagectomy with proximal gastrectomy and was discharged on the 25th hospital day.
Conclusions
We experienced a rare case requiring surgical treatment for a mesh-induced esophageal wall injury after surgery for a giant esophageal hiatal hernia. The selection of a soft, durable mash and its firm securement at a position distant from the gastrointestinal wall may be important to avoid late esophageal wall injury.
Background
Plication of an esophageal hiatus during surgery for esophageal hiatal hernia is a common practice; however, in patients with a markedly large hiatus, a mesh may be used to reinforce the weakened diaphragmatic crura and to close a hiatus that cannot be plicated. Unfortunately, various late complications arising from mesh-induced injuries to the esophageal and/or gastric wall have begun to be reported [1]. Here, we report a patient who required surgery because of an esophageal injury caused by a mesh used in a previous surgery for the repair of a large esophageal hiatal hernia.
Case presentation
A 71-year-old woman visited a neighborhood clinic in November 2010 with chief complaints of respiratory distress on exertion and heartburn. She was referred to us for further medical workup under a suspected diagnosis of esophageal hiatal hernia. Her past history and family history were unremarkable. At the first visit, a physical examination yielded no positive findings, and hematologic/blood biochemical tests also showed no abnormalities. However, a plain chest X-ray revealed a stomach gas bubble that had obliterated the cardiac silhouette within the mediastinum. An abdominal computed tomography (CT) and upper gastrointestinal series revealed an intrathoracic herniation of the stomach, with slight torsion of the corpus ventriculi. The patient was thus diagnosed as having a type IV esophageal hiatal hernia and underwent a laparoscopic Toupet fundoplication in February 2011.
The intraoperative findings revealed a markedly enlarged esophageal hiatal orifice, resulting in the intrusion of the stomach and the greater omentum into the esophageal hiatus. The stomach and greater omentum that had been drawn into the mediastinum through the enlarged esophageal hiatal orifice were restored to their intraperitoneal positions. The esophageal hiatus was plicated dorsally and then ventrally; however, durable closure of the hiatus seemed difficult by this method alone, and mesh reinforcement was subsequently undertaken. A Bard Composite Mesh (PTFP/ePTFP) was cut from the margin to the center and shaped so as to create a keyhole around the abdominal esophagus, with appropriate clearance. To reinforce the hiatus, the mesh was fixed in place using sutures at a distance of about 5 mm from the abdominal esophagus (Fig.1 (A)). Fundoplication was then performed using the Toupet procedure (Fig.1 (B)). The patient had an uneventful postoperative course and was discharged on the 7th hospital day.
The patient visited our outpatient clinic 1 month after the surgery and then once every 2 months. An upper gastrointestinal endoscopy performed 2 months after the surgery revealed no abnormalities. Abdominal CT was not performed, because the patient was asymptomatic and had no laboratory abnormalities. The patient was seen again at the outpatient clinic of this hospital in March 2012, complaining of dysphagia. Both the WBC count and serum CRP were within normal limits. An upper gastrointestinal series revealed the extrusion of the esophagus in a pocket-like shape with stagnated contrast medium. An upper gastrointestinal endoscopy revealed exposure of the mesh at two sites, 36 and 37 cm distal to the incisors, where ulceration causing an esophageal stricture was also found (Fig. 2). A contrast-enhanced CT showed the extrusion of the mesh into the peri-esophageal region and the esophageal lumen (Fig. 3). When the movability of the mesh using forceps was checked, the mesh was found to be firmly adherent. As no improvement of the stricture was noted despite four sessions of endoscopic esophageal dilatation with an 18-mm balloon, we performed a lower esophagus-proximal gastrectomy and esophagogastrostomy in July 2012 (Fig. 4). We packed the hiatal orifice with a reconstructed gastric tube, leaving no room between the hiatus and the reconstructed gastric tube. A partial hepatectomy was also required because of the obstinate adhesion of part of the mesh to the lateral segment of the liver. Lymphocytic infiltration of the mucosa was the only significant pathologic finding. The patient was discharged home on the 25th postoperative day.
Discussion
Esophageal hiatal hernias arise as a result of the weakening of diaphragmatic muscular tissues, often because of aging, and can cause reflux esophagitis. The first surgical treatment for reflux esophagitis was reported by the Mayo Clinic in 1911, and many operative procedures have since been described including the Hill repair method [2], the Nissen method [3], the Balsey Mark IV method [4], and the Toupet procedure. With the spread of minimally invasive laparoscopy during the first half of the 1990s and the report on laparoscopic Nissen fundoplication by Dallemagne et al., laparoscopic surgical practice for esophageal hiatal hernia has become increasingly popular [5].
The guidelines for the management of hiatal hernia established by the Society of American Gastrointestinal Endoscopic Surgeons (SAGES) recommend surgical treatment as follows. (1) All symptomatic paraesophageal hiatal hernias should be repaired, particularly those with acute obstructive symptoms or which have undergone volvulus. (2) Routine elective repair of completely asymptomatic paraesophageal hernias may not always be indicated. Considerations for surgery should include the patient’s age and the presence of co-morbidities. (3) Acute gastric volvulus requires the reduction of the stomach with a limited resection, if needed [6]. In the present case, the patient underwent an operation because she had heartburn and respiratory distress as symptoms of a type IV esophageal hiatal hernia.
Simple closure of the hernial orifice by direct suturing has been commonly performed for the repair of the hernia orifice in esophageal hiatal hernia, and cases with recurrence of the hernia have been reported in which repair using a simple closure resulted in the rupture of the orifice plication, while cases with a large hernial orifice have resulted in intrathoracic wrapping or displacement of the esophagogastric junction [7,8,9]. Repair of a hernial orifice with a mesh has thus been used as a measure to cope with these problems, and Champion and Rock described the efficacy of mesh repair for large hernial orifices exceeding 5 cm [10]. Laparoscopic mesh-augmented hiatoplasty was associated with a lower recurrence rate, compared with a laparoscopic mesh-free hiatoplasty, in a reported by Müller-Stich et al. [11]. In the present case, we performed a laparoscopic Toupet fundoplication and mesh repair for a large esophageal hiatal hernia that could not be closed using a simple laparoscopic closure. The indication for mesh reinforcement in hiatal hernia repair at our hospital was considered for patients with type IV hiatal hernia, large hernial orifice exceeding 5 cm, or fragile hernial orifice.
However, sporadic late complications arising from mesh repair have been reported. Stadlhuber et al. reported 28 cases of postoperative complications after mesh repair for esophageal hiatal hernia. According to their report, the most common chief complaint was dysphagia, followed, in descending order of frequency, by heartburn, chest pain, epigastric pain, and weight loss. Among the reoperated patients, intraesophageal exposure of the mesh occurred in 17 patients, esophageal stricture occurred in 6 patients, and marked fibrosis occurred in 5 patients. No relationship between the development of complications and the type or shape of the mesh used for the repair has been observed [1]. The underlying pathogenetic mechanism is likely as follows: chronic irritation of the esophageal wall and gastric wall caused by the edge of the mesh results in erosions, ulceration, and perforation of the esophageal wall, allowing the passage of the mesh into the gastrointestinal lumen.
We conducted a PubMed search using “hiatal hernia,” “mesh erosion,” and “migration” as key words and retrieved 18 case reports [12,13,14,15,16,17,18,19,20,21,22,23] of mesh exposure in the esophagus or stomach (Table 1). The mean patient age was 61.6 years (12–84 years), the male to female ratio was 1:1.1, and the mean interval from surgical repair until the onset of complications was about 20 months (7 days–108 months). Dysphagia was the most common chief complaint, encountered in 95% of the cases, followed by weight loss in 30%. Other possible symptoms included epigastric pain, heartburn, regurgitation, and bleeding. Most patients had multiple chief complaints. The mesh was made of PTFE/ePTFE in 14 of the 19 reported cases (74%). All the patients had undergone an endoscopic examination for diagnostic purposes. In the present case, the patient had dysphagia for 13 months after the first operation, with an onset that was earlier than that reported in our review. We had used a composite mesh repair in the primary operation. Champion and Rock [10] reported that polypropylene has a propensity to form adhesions and can erode. In the present case, the PTFE/ePTFE mesh might have been responsible for the mesh migration. We cannot reach a consensus as to which type of mesh should be used for surgical treatment because the relationship between mesh material and mesh erosion has not been previously reported. However, the use of a mesh composed of a soft material might reduce the incidence of mesh migration.
Jansen et al. [24] were the first to demonstrate mesh migration into the esophageal wall in a rabbit model. They placed two different types of meshes [polypropylene (PP), Prolene1; polypropylene–polyglecaprone 25 composite (PP-PG), Ultrapro1] on the hiatus as an anterior onlay patch overlapping the hiatal crura at a circular distance of 3 mm from the esophageal wall. The meshes were 2 cm in diameter and were fixed to the diaphragm with four polypropylene (6-0) single stitches. Following this procedure, they found mesh migration into the esophageal wall in six out of seven (86%) animals in the PP group and five out of nine (56%) animals in the PP-PG group. Therefore, it was determined that the distance from the edge of the mesh to the esophageal wall should be more than 3 mm. The larger distance is beneficial for preventing mesh migration, but could also increase the risk of hernia recurrence.
In the present case, the mesh, which was fixed at a distance of 5 mm from the abdominal esophagus, caused esophageal ulceration and eventually became exposed within the esophagus, resulting in dysphagia. The movement of the mesh in the present case might have resulted from chronic irritation exacerbated by peristaltic movements, since the mesh had been fixed close to the esophagus. Therefore, it was suggested that the distance from the edge of the mesh to the esophageal wall should be more than 10 mm to reduce the risk of mesh-induced injuries clinically and practically.
As for the type of mesh selected, friction between the mesh, which was made of a hard material, and the esophageal wall was likely to have exacerbated the irritation of the esophageal wall, resulting in the development of the complication. In cases with postoperative symptoms such as dysphagia and heartburn associated with elevated inflammatory markers on blood biochemistry tests, an upper gastrointestinal endoscopy and CT examination should be considered to rule out possible recurrences or complications caused by the mesh placement, leading to the early discovery of this complication.
While some meta-analyses and systemic reviews have reported on mesh-related complications after laparoscopic repair of giant hiatal hernias, there are no reports comparing the mesh-related complications between patients undergoing laparoscopic repair and those undergoing open repair of giant hiatal hernias [25,26,27]. We believe that adoption of the laparoscopic approach may not be a major cause of this mesh-related complication.
Various reports have described treatments for complications arising from mesh-induced injuries. About 82% of patients with recurrences underwent a reoperation, according to the report by Stadlhuber et al. [1]. The most frequently performed surgical procedure was an esophagectomy, but other procedures included mesh removal by total gastrectomy, partial gastrectomy, or laparotomy. Non-operative procedures that were reported included endoscopic removal and stent placement. Our literature review showed that reoperation was necessary in 68% of cases, and the mesh was removed endoscopically in 21% of the cases. Stent placement and balloon dilation were performed in 2 of the 19 reported cases (10%). Endoscopic balloon dilatation is not a radical treatment for esophageal stenosis caused by a mesh. Rather than endoscopic treatment, mesh excision should be performed to obtain a good outcome. In the present case, we attempted to remove the mesh during an upper gastrointestinal endoscopy using balloon dilation. Our attempt failed, however, because of the presence of firmly adherent tissue and fibrous tissue incorporation. Surgery should be considered when a cure cannot be achieved endoscopically. The methods used to treat complications, including surgery, should be decided in accordance with the disease condition, and reoperation has been undertaken in many cases; therefore, the selection of the mesh, including consideration of its material composition, at the time of the initial operation and the position and distance from the esophageal hiatus at which the mesh is fixed are of clinical importance.
Conclusion
Currently, a wide variety of mesh types are available, and guidelines for the appropriate use of meshes are being examined; therefore, the further accumulation of cases is necessary. Simple plication without the use of a mesh should be considered as the method of first choice for preventing mesh-related complications. Nevertheless, for cases with a large esophageal hiatal hernia, in which the use of a mesh cannot be avoided, it is important to select a soft, durable mesh and to secure it firmly in place at a position distant from the gastrointestinal wall.
Abbreviations
- CT:
-
Computed tomography
- EGJ:
-
Esophagogastric junction
- ePTFP:
-
Expanded polytetrafluoroethylene
- F:
-
Female
- M:
-
Male
- PTFP:
-
Polytetrafluoroethylene
References
Stadlhuber RJ, Sherif AE, Mittal SK, Fitzgibbons RJ Jr, Michael Brunt L, Hunter JG, DeMeester TR, Swanstrom LL, Smith CD, Filipi CJ. Mesh complications after prosthetic reinforcement of hiatal closure: a 28-case series. Surg Endosc. 2009;23:1219–26.
Hill LD. An effective operation for hiatal hernia: an eight year appraisal. Ann Surg. 1967;166:681–92.
Nissen R. Gastropexy and “fundoplication” in surgical treatment of hiatus hernia. Am J Dig Dis. 1961;6:954–61.
Skinner DB, Belsey RH. Surgical management of esophageal reflux and hiatus hernia. Long-term results with 1,030 patients. J Thorac Cardiovasc Surg. 1967;53:33–54.
Dallemagne B, Weerts JM, Jehaes C, Markiewicz S, Lombard R. Laparoscopic Nissen fundoplication: preliminary report. Surg Laparosc Endosc. 1991;1:138–42.
Kohn GP, Price RR, DeMeester SR, Zehetner J, Muensterer OJ, Awad Z, Mittal SK, Richardson WS, Stefanidis D, Fanelli RD; SAGES Guidelines Committee. Guidelines for the management of hiatal hernia. Surg Endosc. 2013;27:4409-28.
Carlson MA, Frantzides CT. Complication and results of primary minimally invasive antireflux procedures: a review of 10,735 reported case. J Am Coll Surg. 2001;193:428–39.
Hunter JG, Smith CD, Branum CD. Laparoscopic fundoplication failures: patterns of failure and response to fundoplication revision. Ann Surg. 1999;230:595–606.
Soper NJ, Dunnegan D. Anatomic fundoplication failure after laparoscopic antireflux surgery. Ann Surg. 1999;229:669–76.
Champion JK, Rock D. Laparoscopic mesh cruroplasty for large paraesophageal hernias. Surg Endosc. 2003;17:551–3.
Müller-Stich BP, Kenngott HG, Gondan M, Stock C, Linke GR, Fritz F, Nickel F, Diener MK, Gutt CN, Wente M, Büchler MW, Fischer L. Use of mesh in laparoscopic Paraesophageal hernia repair: a meta-analysis and risk-benefit analysis. PLoS One. 2015; https://doi.org/10.1371/journal.pone.0139547.
Dutta S. Prosthetic esophageal erosion after mesh hiatoplasty in a child, removed by transabdominal endogastric surgery. J Pediatr Surg. 2007;42:252–6.
Griffith PS, Valenti V, Qurashi K, Martinez-Isla A. Rejection of goretex mesh used in prosthetic cruroplasty. Int J Surg. 2008;6:106–9.
Acin-Gandara D, Miliani-Molina C, Carneros-Martin J, Martinez-Pineiro J, Vega MD, Pereira-Perez F. Transmural gastric migration of dual-sided PTFE/ePTFE mesh after laparoscopic surgery for a recurrent hiatal hernia with dysphagia. Chirurg. 2014;109:538–41.
Carpelan-Holmström M, Kruuna O, Salo J, Kylänpää L, Scheinin T. Late mesh migration through the stomach wall after laparoscopic refundoplication using a dual-sided PTFE/ePTFE mesh. Hernia. 2011;15:217–20.
Kepenekci I, Turkcapar AG. Mesh erosion as a complication of laparoscopic fundoplication with prosthetic hiatal closure: report of a case. Surg Laparosc Endosc Percutan Tech. 2009;19:e51–4.
Hazebroek EJ, Leibman S, Smith GS. Erosion of a composite PTFE/ePTFE mesh after hiatal hernia repair. Surg Laparosc Endosc Percutan Tech. 2009;19:175–7.
Zügel N, Lang RA, Kox M, Hüttl TP. Severe complication of laparoscopic mesh hiatoplasty for paraesophageal hernia. Surg Endosc. 2009;23:2563–7.
De Moor V, Zalcman M, Delhaye M, El Nakadi I. Complications of mesh repair in hiatal surgery: about 3 cases and review of the literature. Surg Laparosc Endosc Percutan Tech. 2012;22:e222–5.
Porziella V, Cesario A, Lococo F, Margaritora S, Leuzzi G, Marchese M, Petruzziello L, Costamagna G, Granone P. Complete transmural gastric migration of PTFE mesh after surgery for a recurrent hiatal hernia. Eur Rev Med Pharmacol Sci. 2012;16(Suppl 4):42–3.
Arroyo Q, Argüelles-Arias F, Jimenez-Saenz M, Herrerias-Gutierrez JM, Pellicer Bautista F, Rodríguez-Téllez M. Dysphagia caused by migrated mesh after paraesophageal hernia repair. Endoscopy. 2011;43:E257–8.
Liang WT, Hu ZW, Wang ZG, Wu JM, Liang Y. Mesh-related complications after hiatal hernia repair: two case reports. Gastroenterol Nurs. 2015;38:226–9.
Tatum RP, Shalhub S, Oelschlager BK, Pellegrini CA. Complications of PTFE mesh at the diaphragmatic hiatus. J Gastrointest Surg. 2008;12:953–7.
Jansen M, Otto J, Jansen PL, Anurov M, Titkova S, Willis S, Rosch R, Ottinger A, Schumpelick V. Mesh migration into the esophageal wall after mesh hiatoplasty: comparison of two alloplastic materials. Surg Endosc. 2007;21:2298–303.
Huddy JR, Markar SR, Ni MZ, Morino M, Targarona EM, Zaninotto G, Hanna GB. Laparoscopic repair of hiatus hernia: does mesh type influence outcome? A meta-analysis and European survey study. Surg Endosc. 2016;30:5209–21.
Tam V, Winger DG, Nason KS. A systematic review and meta-analysis of mesh vs suture cruroplasty in laparoscopic large hiatal hernia repair. Am J Surg. 2016;211:226–38.
Memon MA, Memon B, Yunus RM, Khan S. Suture Cruroplasty versus prosthetic Hiatal Herniorrhaphy for large Hiatal hernia: a meta-analysis and systematic review of randomized controlled trials. Ann Surg. 2016;263:258–66.
Author information
Authors and Affiliations
Contributions
All authors have made substantial contributions to the conception and design of the case report. SO and EI underwent the operation. All authors read and approved the final manuscript.
Corresponding author
Ethics declarations
Author’s information
KY and MN and YN are students of Tokai University Graduate School of Medicine, SO is a Professor and Chairman of Department of Gastroenterological Surgery, JO is an Associate Professor of Department of Gastroenterological Surgery, and EI and AK are Assistant Professor of Department of Gastroenterological Surgery.
Consent for publication
Written informed consent was obtained from the patient for publication of this case report and any accompanying images.
Competing interests
The authors declare that they have no competing interests.
Publisher’s Note
Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.
Rights and permissions
Open Access This article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made.
About this article
Cite this article
Yatabe, K., Ozawa, S., Ito, E. et al. Late esophageal wall injury after mesh repair for large esophageal hiatal hernia: a case report. surg case rep 3, 125 (2017). https://doi.org/10.1186/s40792-017-0401-4
Received:
Accepted:
Published:
DOI: https://doi.org/10.1186/s40792-017-0401-4